Diagnostic Performance of 64-Multidetector Row Coronary Computed

Objectives

The purpose of this study was to evaluate the diagnostic accuracy of electrocardiographically gated 64-multidetector row coronary computed tomographic angiography (CCTA) in individuals without known coronary artery disease (CAD).
Background CCTA is a promising method for detection and exclusion of obstructive coronary artery stenosis. To date, no prospective multicenter trial has evaluated the diagnostic accuracy of 64-multidetector row CCTA in populations with intermediate prevalence of CAD.

Cardiac Computed Tomography


Methods

We prospectively evaluated subjects with chest pain at 16 sites who were clinically referred for invasive coronary angiography (ICA). CCTAs were scored by consensus of 3 independent blinded readers. The ICAs were evaluated for coronary stenosis based on quantitative coronary angiography (QCA). No subjects were excluded for baseline coronary artery calcium score or body mass index. Results A total of 230 subjects underwent both CCTA and ICA (59.1% male; mean age: 57 ± 10 years).
On a patient based model, the sensitivity, specificity, and positive and negative predictive values to detect ≥50% or ≥70% stenosis were 95%, 83%, 64%, and 99%, respectively, and 94%, 83%, 48%, 99%, respectively.
No differences in sensitivity and specificity were noted for nonobese compared with obese subjects or for heart rates ± 65 beats/ min compared with >65 beats/min, whereas calcium scores >400 reduced specificity significantly.

Conclusion:

In this prospective multicenter trial of chest pain patients without known CAD, 64-multidetector row CCTA possesses high diagnostic accuracy for detection of obstructive coronary stenosis at both thresholds of 50% and 70% stenosis. Importantly, the 99% negative predictive value at the patient and vessel level establishes CCTA as an effective noninvasive alternative to ICA to rule out obstructive coronary artery stenosis.

J Am Coll Cardiol 2008; in press

The diagnostic accuracy of cardiac CT could be proven by many studies, especially to rule out the presence of significant coronary lesions. One limitation and important issue of criticism was the lack of prospective multi-center trials, since most studies had been performed by single centres.

Budoff et al present the data of the ACCURACY trial, a multi-center study, using 64-slice CT in more than 200 pts. Again, the negative predictive was very high, underlining the value of cardiac CT for ruling out the presence of significant lesions.

Notes to editor


Matthew J. Budoff, MD,David Dowe, MD,James G. Jollis, MD,Michael Gitter, MD,
John Sutherland, MD, Edward Halamert, MD, Markus Scherer, MD,
Raye Bellinger, MD, Arthur Martin, MD, Robert Benton, MD,
Augustin Delago, MD, James K.Min  MD
The content of this article reflects the personal opinion of the author/s and is not necessarily the official position of the European Society of Cardiology.